A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion

https://fmu.repo.nii.ac.jp/records/2002034
https://fmu.repo.nii.ac.jp/records/2002034
01aeccef-8a52-44a5-adac-0d1d7fccaaec
名前 / ファイル ライセンス アクション
FksmJMedSci_67_p161.pdf FksmJMedSci_67_p161.pdf (715.9 KB)
Item type デフォルトアイテムタイプ(フル)fmu(1)
公開日 2021-12-23
タイトル
タイトル A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
言語 en
作成者 Tashiro, Masami

× Tashiro, Masami

en Tashiro, Masami

Search repository
Kubo, Hitoshi

× Kubo, Hitoshi

en Kubo, Hitoshi

Search repository
Kanezawa, Chie

× Kanezawa, Chie

en Kanezawa, Chie

Search repository
Ito, Hiroshi

× Ito, Hiroshi

en Ito, Hiroshi

Search repository
権利情報
権利情報Resource https://creativecommons.org/licenses/by-nc-sa/4.0/
権利情報 © 2021 The Fukushima Society of Medical Science. This article is licensed under a Creative Commons [Attribution-NonCommercial-ShareAlike 4.0 International] license.
内容記述
内容記述タイプ Abstract
内容記述 A central venous catheter (CVC) should be inserted at the optimum position to infuse medicines, blood products, nutrients, or fluids. Positioning of the catheter tip is commonly performed under landmark or fluoroscopic guidance. However, Japanese regulations do not allow the performing of fluoroscopy-guided procedures outside of the fluoroscopy room. We hypothesized that a new image-guided CVC placement technique by combining a wireless flat-panel detector (FPD) and a mobile X-ray system could be applied at the bedside to support CVC insertion. A CVC attached to a chest phantom in conjunction with the polymethyl methacrylate (PMMA) phantom was imaged, contrast-to-noise ratio (CNR) was measured with images, and radiologists and emergency physicians rated the catheter images using a Likert scale for visual evaluation. The minimum dose of the FPD and mobile X-ray system was reduced by at least 98% compared with that of the X-ray fluoroscopy system. The CNR decreased with the increasing PMMA phantom thickness. However, results of the visual evaluation were maintained at the clinically usable score with low-dose imaging up to a 6-cm thickness of the PMMA phantom. In conclusion, the combination of FPD and mobile X-ray systems is particularly effective in the emergency room setting where such procedures are required to be performed with urgency.
出版者
出版者 The Fukushima Society of Medical Science
言語
言語 eng
書誌情報 en : Fukushima Journal of Medical Science

巻 67, 号 3, p. 161-167, 発行日 2021
関連情報
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.5387/fms.2021-27
関連情報
識別子タイプ PMID
関連識別子 34937810
関連情報
識別子タイプ ICHUSHI
関連識別子 2023054399
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0016-2590
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2185-4610
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA0065246X
主題
主題Scheme Other
主題 Image-guided catheter insertion
主題
主題Scheme Other
主題 Flat-panel detector (FPD)
主題
主題Scheme Other
主題 Mobile X-ray system
主題
主題Scheme Other
主題 Low radiation dose
戻る
0
views
See details
Views

Versions

Ver.1 2024-12-02 10:13:41.963091
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3