ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 医学部
  2. 学術雑誌論文

Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection using aerobic culture

https://fmu.repo.nii.ac.jp/records/2000001
https://fmu.repo.nii.ac.jp/records/2000001
21a47c67-fd43-4150-9934-8c5df12838bb
名前 / ファイル ライセンス アクション
Transfusion_47_2044.pdf Transfusion_47_2044.pdf (287.0 KB)
Item type デフォルトアイテムタイプ(フル)fmu(1)
公開日 2010-05-24
タイトル
タイトル Culture-based bacterial detection systems for platelets: the effect of time prior to sampling and duration of incubation required for detection using aerobic culture
言語 en
作成者 Ezuki, Shoji

× Ezuki, Shoji

en Ezuki, Shoji

Search repository
Kawabata, Kinuyo

× Kawabata, Kinuyo

en Kawabata, Kinuyo

Search repository
Kanno, Takahiro

× Kanno, Takahiro

en Kanno, Takahiro

Search repository
Ohto, Hitoshi

× Ohto, Hitoshi

en Ohto, Hitoshi

Search repository
権利情報
権利情報 © 2007 American Association of Blood Banks. The definitive version is available at www.blackwell-synergy.com
内容記述
内容記述タイプ Abstract
内容記述 BACKGROUND: Bacterial contamination of platelet products (PLTs) occurs at low concentrations requiring a period of incubation for growth to minimize sampling error. Culture-based detection methods also need sufficient incubation time; together these periods may limit the useful life of PLTs. This study characterizes the impact of sampling and detection times using two commercially-available bacteria detection products.\nSTUDY DESIGN AND METHODS: Apheresis PLTs inoculated with nine bacterial species at low concentrations were sampled immediately, and after 24 hours following inoculation. Test results were analyzed following incubation at 16, 20 and 24 hours after sampling using two bacterial detection systems. RESULTS: When sampled immediately after inoculation, BacT/ALERT (BioMerieux) and Pall eBDS (Pall Corporation) failed to detect some PLTs inoculated with S. epidermidis, S. liquefaciens or P. aeruginosa and S. epidermidis, S. liquefaciens, B. cereus or P. aeruginosa, respectively. The BacT/ALERT was better at 20 hours (p<0.02), but not at 16 or 24 hours for time 0 sampling. When sampling occurred 24 hours after inoculation, there were no difference between the two systems. CONCLUSION: Results suggest that for either bacteria detection system, holding PLTs for 24 hrs prior to sampling improves the detection sensitivity for PLTs contaminated with low concentrations of bacteria and longer incubation periods improve detection.
出版者
出版者 Blackwell Publishing Inc
言語
言語 eng
書誌情報 en : Transfusion

巻 47, 号 11, p. 2044-2049, 発行日 2007-11
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1111/j.1537-2995.2007.01428.x
関連情報
識別子タイプ PMID
関連識別子 17958533
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0041-1132
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 1537-2995
収録物識別子
収録物識別子タイプ NCID
収録物識別子 AA00868753
主題
主題Scheme MeSH
主題 Aerobiosis
主題
主題Scheme MeSH
主題 Bacteria
主題
主題Scheme MeSH
主題 Bacteriological Techniques
主題
主題Scheme MeSH
主題 Blood Platelets
主題
主題Scheme MeSH
主題 Humans
主題
主題Scheme MeSH
主題 Reagent Kits, Diagnostic
戻る
0
views
See details
Views

Versions

Ver.1 2024-11-12 05:06:03.710227
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3