{"created":"2024-11-12T05:06:05.651515+00:00","id":2000003,"links":{},"metadata":{"_buckets":{"deposit":"aea5797a-fd60-4b1b-bf30-f39b9a286cfe"},"_deposit":{"created_by":8,"id":"2000003","owners":[8],"pid":{"revision_id":0,"type":"depid","value":"2000003"},"status":"published"},"_oai":{"id":"oai:fmu.repo.nii.ac.jp:02000003","sets":["1623632832836:1730783669761"]},"author_link":[],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_title":"Survival and recovery of apheresis platelets stored in a polyolefin container with high oxygen permeability","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"Creator","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ezuki, Shoji","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kanno, Takahiro","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Ohto, Hitoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Herschel, Louise","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Ito, Takatoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kawabata, Kinuyo","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Seino, Osamu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Ikeda, Kazuhiko","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Nollet, Kenneth E","creatorNameLang":"en"}]}]},"item_1617186499011":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_rights":"Journal compilation © 2008 Blackwell Publishing Ltd. The definitive version is available at www.blackwell-synergy.com","subitem_rights_language":"en"}]},"item_1617186609386":{"attribute_name":"Subject","attribute_value_mlt":[{"subitem_subject":"platelet storage","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"in vitro platelet quality","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"in vivo platelet recovery","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"platelet survival","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"kinetics","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Blood Banks","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Blood Gas","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Blood Platelets","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Humans","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Hydrogen-Ion Concentration","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Oxygen","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Permeability","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Plastics","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Platelet Transfusion","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Plateletpheresis","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Polyenes","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"},{"subitem_subject":"Specimen Handling","subitem_subject_language":"en","subitem_subject_scheme":"MeSH"}]},"item_1617186626617":{"attribute_name":"Description","attribute_value_mlt":[{"subitem_description":"Background and Objectives Oxygen permeability is important in platelet storage media. We compared a new polyolefin container with enhanced oxygen permeability (PO-80, Kawasumi, Tokyo, Japan) to a widely used alternative (PL2410, Baxter Healthcare, Illinois, USA). Materials and Methods In vitro characteristics of paired platelet concentrates (PCs, mean 4.2×1011/250 ml plasma/bag) stored in PO-80 or PL2410 were assessed through nine days of storage. In vivo recovery and survival of seven-day-old autologous PCs were assessed according to the Murphy method. Results Laboratory assessment of platelet quality favored PO-80 during nine days of storage with statistically significant differences in glucose consumption (2.75 vs. 4.93 mmol/1012/24hrs in the interval 120-168 hrs), lactate generation (4.37 vs. 8.11 mmol/1012/24hrs in the interval 120-168 hrs), pO2 (59.3 vs. 38.1 mmHg at day 1), and HCO3- (14.7 vs. 13.4 mmol/L at day 1). Statistically significant differences were not seen in aggregation, hypotonic shock response, or pH. In vivo assessment of autologous platelets stored seven days in the PO-80 container revealed that recovery was 82.1% and survival was 81.0% of fresh control. Seven-day-stored PCs in PO-80 were shown in vivo to be noninferior to fresh platelets, with upper confidence limits (UCL95) in recovery and survival of stored PCs below the maximum acceptable difference (MAD); 15.3% UCL95 < 20.4% MAD and 2.1 days UCL95 < 2.1 days MAD. Conclusions The in vitro characteristics of PCs stored in a highly oxygen-permeable container were stable at least seven days. The in vivo study supports the suitability of PO-80 for seven-day platelet storage.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_1617186643794":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"Blackwell Publishing Ltd.","subitem_publisher_language":"en"}]},"item_1617186702042":{"attribute_name":"Language","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_1617186920753":{"attribute_name":"Source Identifier","attribute_value_mlt":[{"subitem_source_identifier":"0042-9007","subitem_source_identifier_type":"PISSN"},{"subitem_source_identifier":"1423-0410","subitem_source_identifier_type":"EISSN"},{"subitem_source_identifier":"AA00885402","subitem_source_identifier_type":"NCID"}]},"item_1617187056579":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"298","bibliographicPageStart":"292","bibliographicVolumeNumber":"94","bibliographic_titles":[{"bibliographic_title":"Vox Sanguinis","bibliographic_titleLang":"en"}]}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"Version Type","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_1617353299429":{"attribute_name":"Relation","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1111/j.1423-0410.2008.01042.x","subitem_relation_type_select":"DOI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"18331381","subitem_relation_type_select":"PMID"}}]},"item_1617605131499":{"attribute_name":"File","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2010-05-24"}],"displaytype":"detail","filename":"VoxSang_94_292.pdf","filesize":[{"value":"227.0 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"url":"https://fmu.repo.nii.ac.jp/record/2000003/files/VoxSang_94_292.pdf"},"version_id":"6a2038d2-8a02-4995-906c-7c3f4079090c"}]},"item_title":"Survival and recovery of apheresis platelets stored in a polyolefin container with high oxygen permeability","item_type_id":"40002","owner":"8","path":["1730783669761"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-05-24"},"publish_date":"2010-05-24","publish_status":"0","recid":"2000003","relation_version_is_last":true,"title":["Survival and recovery of apheresis platelets stored in a polyolefin container with high oxygen permeability"],"weko_creator_id":"8","weko_shared_id":-1},"updated":"2025-01-07T06:26:50.416097+00:00"}